Files
kaptan/firmware/libs/kaptan-mavlink/definitions/publish/log.xml
T

32 lines
1.5 KiB
XML

<?xml version="1.0"?>
<mavlink>
<version>3</version>
<dialect>0</dialect>
<enums>
<enum name="LOG_LEVEL">
<entry value="0" name="LOG_LEVEL_OFF">
<description>Filter-only sentinel. A LOG event must not use this value.</description>
</entry>
<entry value="1" name="LOG_LEVEL_TRACE"/>
<entry value="2" name="LOG_LEVEL_DEBUG"/>
<entry value="3" name="LOG_LEVEL_INFO"/>
<entry value="4" name="LOG_LEVEL_WARN"/>
<entry value="5" name="LOG_LEVEL_ERROR"/>
</enum>
<enum name="LOG_FLAGS" bitmask="true">
<entry value="1" name="LOG_FLAG_TRUNCATED">
<description>Message text was truncated to the bounded on-wire buffer.</description>
</entry>
</enum>
</enums>
<messages>
<message id="51020" name="LOG">
<description>Bounded human-readable runtime log emitted by every Kaptan logging macro, including error. The receiver needs only level, flags, and the valid UTF-8 text prefix. MAVLink framing, bounded admission, DMA, and retries remain platform-owned.</description>
<field type="uint8_t" name="level" enum="LOG_LEVEL">Kaptan wire level.</field>
<field type="uint8_t" name="flags" enum="LOG_FLAGS">TRUNCATED=1. Receivers ignore unrecognized bits.</field>
<field type="uint8_t" name="message_length">Number of valid UTF-8 bytes in message; at most 160.</field>
<field type="uint8_t[160]" name="message">Bounded UTF-8 message bytes. Bytes after message_length are zero.</field>
</message>
</messages>
</mavlink>